High Pressure Drop Steam Control Valves
Multistage steam pressure-reducing control valves for power plants and industrial steam systems. Junkang selects the valve and trim based on pressure ratio, steam flow, outlet velocity and your noise limit.
Category:
Application
Email:
Product Description
Power plants and industrial steam systems use pressure-reducing control valves to supply lower-pressure headers from a higher-pressure steam source. The valve must cover the required flow range while accounting for steam expansion, outlet velocity and aerodynamic noise. Typical duties include steam header letdown and pressure control in pressure-reducing and desuperheating stations.
Valve and trim options
JKS Multi-Stage Cage Control Valve
JKS is a complete globe control valve with concentric cage stages that distribute a large pressure drop across multiple restrictions. Junkang selects the valve size, body rating, cage capacity and number of stages for the specified steam duty.
AeroCalm perforated cage trim
AeroCalm divides the steam flow into multiple small jets to manage aerodynamic noise. One to five pressure-reduction stages are available, depending on the trim configuration.
MazeFlow labyrinth trim
MazeFlow routes steam through a series of turns and restrictions. Consider this trim for severe letdown where staging is needed to manage flow velocity and noise across a large pressure drop.
Operating data for valve sizing
- Inlet and outlet pressures at minimum, normal and maximum flow. Specify gauge or absolute pressure.
- Steam temperature and state, with mass flow for each operating point.
- Upstream and downstream pipe sizes and schedules, valve connection and required pressure class.
- Allowable noise in dB(A), measurement location and shutoff requirements.
Junkang reviews the required Cv at each duty point, the possibility of choked flow, outlet velocity and trim staging. Predicted aerodynamic noise depends on the selected valve, trim, operating conditions and piping.
certification
Related Products
Reverse Blower Integral Double Gate Valve
Electric Balanced Sleeve-Guided Globe Control Valve with Side Handwheel
Self-Operated Boiler Steam Pressure Regulator
Manual Ceramic Wear Resistant Open Rod Hidden Rod Insert Plate Slurry Knife Gate Valve
Message
For a valve quote, please include the process fluid, flow rate, inlet pressure, outlet pressure, and operating temperature, with units.